ATCC ATCC Logo 0
  • Quick Order
  • Careers
  • Support

Acetobacterium fimetarium Kotsyurbenko et al.

51795

Product category
Bacteria
Strain designation
Z-4290 [DSM 8238]
Type strain
Yes
Isolation source
Manure
Buy Now
Price: $620.00 EA
Discounts may be available for our fellow nonprofit organizations. Login to see your price.

Generally ships within 1-3 business days

Documentation

ATCC determines the biosafety level of a material based on our risk assessment as guided by the current edition of Biosafety in Microbiological and Biomedical Laboratories (BMBL), U.S. Department of Health and Human Services. It is your responsibility to understand the hazards associated with the material per your organization’s policies and procedures as well as any other applicable regulations as enforced by your local or national agencies.

ATCC highly recommends that appropriate personal protective equipment is always used when handling vials. For cultures that require storage in liquid nitrogen, it is important to note that some vials may leak when submersed in liquid nitrogen and will slowly fill with liquid nitrogen. Upon thawing, the conversion of the liquid nitrogen back to its gas phase may result in the vial exploding or blowing off its cap with dangerous force creating flying debris. Unless necessary, ATCC recommends that these cultures be stored in the vapor phase of liquid nitrogen rather than submersed in liquid nitrogen.

Detailed product information

General

Preceptrol
No

Handling information

Medium
Temperature
20°C
Atmosphere
80% N2, 20% H2
Handling procedure
1.       Open vial according to enclosed instructions.

2.       Under anaerobic conditions, withdraw 0.5 ml of the recommended broth from a single tube (5 to 6 ml) and rehydrate the vial contents.

4. Incubate tubes under an anaerobic atmosphere at 20oC.  Incubate one agar plate anaerobically for colony formation, and one aerobically for aerobic contamination check.

5. In 48 hours, growth should be evident by turbidity that settles to the bottom of the tube.  No growth should occur on agar plate incubated aerobically.

ANAEROBIC CONDITIONS:

a.       Balch tubes (available from Bellco Glass, Vineland, NJ; are specially designed for anaerobic work and use an aluminum crimp cap to hold a rubber stopper in place. Needles can easily be inserted through the stopper, and the tubes can be pressurized to 2 atm.  Alternatively, serum vials may be used, or screw cap tubes with butyl rubber stoppers, in the latter case the stopper may be removed and the tube placed under a cannula system that dispenses sterile, oxygen free gas for addition of reducing agents or inoculation.

b. Resazurin is a commonly used redox indicator that is pink when the redox potential is above –50 mv, and colorless when the redox potential is below –110 mv, i.e. highly reducing.  Most strict anaerobes require this low redox potential for optimum growth.

c.  To obtain a fully reduced medium, it is necessary that the medium be anoxic and that a reducing agent be added.  Common reducing agents are sodium sulfide, cysteine, dithiothreitol, and titanium citrate.

d. Syringes can be made anaerobic by one of two methods. 

          1.     Displace the dead space in the syringe with a sterile

2.       Displace the dead space in the syringe with a

Handling notes
          Additional information on this culture is available on the ATCC web site at www.atcc.org.

          While every effort is made to insure authenticity and reliability of strains on deposit, ATCC is not liable for damages arising from the misidentification or misrepresentation of cultures.

          ATCC recommends that individuals contemplating commercial use of any culture first contact the originating investigator to negotiate an agreement.  Third party distribution of this culture is discouraged, since this practice has resulted in the unintentional spreading of contaminated cultures.

History

Deposited as
Acetobacterium fimetarium Kotsyurbenko et al.
Depositors
OR Kotsyurbenko
Type of isolate
Animal

Legal disclaimers

Intended use
This product is intended for laboratory research use only. It is not intended for any animal or human therapeutic use, any human or animal consumption, or any diagnostic use.
Warranty

The product is provided 'AS IS' and the viability of ATCC® products is warranted for 30 days from the date of shipment, provided that the customer has stored and handled the product according to the information included on the product information sheet, website, and Certificate of Analysis. For living cultures, ATCC lists the media formulation and reagents that have been found to be effective for the product. While other unspecified media and reagents may also produce satisfactory results, a change in the ATCC and/or depositor-recommended protocols may affect the recovery, growth, and/or function of the product. If an alternative medium formulation or reagent is used, the ATCC warranty for viability is no longer valid.  Except as expressly set forth herein, no other warranties of any kind are provided, express or implied, including, but not limited to, any implied warranties of merchantability, fitness for a particular purpose, manufacture according to cGMP standards, typicality, safety, accuracy, and/or noninfringement.

Disclaimers

This product is intended for laboratory research use only. It is not intended for any animal or human therapeutic use, any human or animal consumption, or any diagnostic use. Any proposed commercial use is prohibited without a license from ATCC.

While ATCC uses reasonable efforts to include accurate and up-to-date information on this product sheet, ATCC makes no warranties or representations as to its accuracy. Citations from scientific literature and patents are provided for informational purposes only. ATCC does not warrant that such information has been confirmed to be accurate or complete and the customer bears the sole responsibility of confirming the accuracy and completeness of any such information.

This product is sent on the condition that the customer is responsible for and assumes all risk and responsibility in connection with the receipt, handling, storage, disposal, and use of the ATCC product including without limitation taking all appropriate safety and handling precautions to minimize health or environmental risk. As a condition of receiving the material, the customer agrees that any activity undertaken with the ATCC product and any progeny or modifications will be conducted in compliance with all applicable laws, regulations, and guidelines. This product is provided 'AS IS' with no representations or warranties whatsoever except as expressly set forth herein and in no event shall ATCC, its parents, subsidiaries, directors, officers, agents, employees, assigns, successors, and affiliates be liable for indirect, special, incidental, or consequential damages of any kind in connection with or arising out of the customer's use of the product. While reasonable effort is made to ensure authenticity and reliability of materials on deposit, ATCC is not liable for damages arising from the misidentification or misrepresentation of such materials.

Please see the material transfer agreement (MTA) for further details regarding the use of this product. The MTA is available at www.atcc.org.

Permits & Restrictions

Import Permit for the State of Hawaii

If shipping to the U.S. state of Hawaii, you must provide either an import permit or documentation stating that an import permit is not required. We cannot ship this item until we receive this documentation. Contact the Hawaii Department of Agriculture (HDOA), Plant Industry Division, Plant Quarantine Branch to determine if an import permit is required.

MORE INFORMATION ABOUT PERMITS AND RESTRICTIONS

Frequently Asked Questions

References

Curated Citations

Validation list no. 60. Int. J. Syst. Bacteriol. 47: 242, 1997.

Kotsyurbenko OR, et al. New species of psychrophilic acetogens: Acetobacterium bakii sp. nov., A. paludosum sp. nov., A. fimetarium sp. nov.. Arch. Microbiol. 163: 29-34, 1995.

type strain

digested manure

Need assistance with this product? Contact our Technical Support team.

Telephone

US and Puerto Rico
800-638-6597

Outside the US
+1-703-365-2700

Hours of Operation

Monday-Friday
9:00am - 5:00pm
US Eastern Time